OUTAGE STACK

Stack / F2000

Anker SOLIX F2000

Updated · 16 Sep 2026 · Sheet checked · 16 Sep 2026

Buy — 2,400 W continuous / 2,048 Wh LFP expandable to ~4 kWh; TT-30; not F3800; not 240 V; 3,600 W marketing ≠ continuous

POWER STATION

Wheeled ~67 lb LiFePO₄ station: model A1780 (also PowerHouse 767). 2,400 W continuous AC Max / marketing peak up to 3,600 W (not continuous). 2,048 Wh LFP base, expandable to 4,096 Wh with one 760 / BP2000 pack. 120 V only. TT-30R shares the 2,400 W ceiling with the NEMA-20R bank. Solar up to 1,000 W XT-60. Not F3800, not dual-voltage, not 240 V.

2,400 WAC continuous
2,048 WhBase LFP → ~4 kWh
~67.2 lbWheeled
120 VTT-30 · not 240

Will run

  • Fridge-class essentials + lights + network under 2,400 W continuous
  • RV TT-30 loads within the shared 2.4 kW ceiling
  • Wh expand via one 760 / BP2000 pack (duration, not higher continuous AC)

Skip, or measure first

  • Treating 3,600 W marketing peak as continuous — size to 2,400 W
  • Native 240 V well / dryer / dual-V panel work — that is F3800
  • Confusing with F3800, F2600, or C2000 Gen 2; BP3800 / BP2000 Gen 2 packs

What it is

US Anker SOLIX F2000 only (A1780 / PowerHouse 767): 2,048 Wh LFP, 120 V~ 20 A 60 Hz, 2,400 W Max AC in inverter mode; ~67.2 lb wheeled; 20.7 × 15.5 × 9.8 in. One Anker 760 (BP2000 for F2000/F2600) → 4,096 Wh. Solar XT-60 up to 1,000 W. AC charge in 1,440 W Max. Distinct from already-live Anker SOLIX F3800. Desk review of manufacturer claims — not a cycle-life bench. Outage Stack planning assumption (not manufacturer): usable Wh = rated Wh × 0.85. At a 500 W load: 2,048 × 0.85 ÷ 500 ≈ 3.4 h.

Verdict

Buy for a coherent indoor-friendly 2,400 W continuous / 2,048 Wh LFP station with real TT-30R, 1,000 W solar ceiling, and clean one-pack expansion to ~4 kWh. Skip if you meant F3800 (6,000 W continuous, 120/240 V), need a ~40 lb carry, or thought 3,600 W marketing was all-day continuous.

Source: Anker SOLIX F2000 · A1780 manual

Anker SOLIX F3800 → · Size guide →